For the electronic measurement of currents : DC, AC, pulsed...,with a galvanic isolation between the primary circuit (high power)and the secondary circuit (electronic circuit).
Electrical data
I PN Primary nominal r.m.s. current 1000A
I P Primary current, measuring range 0 .. ± 1500A
R M
Measuring resistance @ T A = 70°C T A = 85°C
R M min R M max R M min R M max
with ± 15 V @ ± 1000 A max 018015Ω@ ± 1200 A max 0 70 4Ωwith ± 24 V
@ ± 1000 A max 5 60.510 57.5Ω@ ± 1500 A max
5241021
Ω
I SN Secondary nominal r.m.s. current 200m A K N Conversion ratio
1 : 5000V C Supply voltage (± 5 %)± 15 .. 24V I C Current consumption
20 (@ ± 24 V ) + I S m A V d
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 3k V
Accuracy - Dynamic performance data
X G
Overall accuracy @ I PN , T A = 25°C
± 0.4%ε
L
Linearity
< 0.1%Typ
Max I O Offset current @ I P = 0, T A = 25°C ± 0.4m A I OT Thermal drift of I O
- 10°C .. + 85°C ± 0.3
± 0.5
m A t r
Response time 1)
@ 90 % of I PN < 1µs di/dt di/dt accurately followed
> 100A/µs f
Frequency bandwidth (- 1 dB)
DC .. 150
kHz
General data
T A Ambient operating temperature - 10 .. + 85°C T S Ambient storage temperature - 25 .. + 100°C R S Secondary coil resistance @T A = 70°C 48ΩT A = 85°C
51Ωm
Mass
500
g
Standards 2)
EN 50178
Notes :
1)With a di/dt of 100 A/µs
2)
A list of corresponding tests is available.
Features
•Closed loop (compensated) current
transducer using the Hall effect •Insulated plastic case recognized according to UL 94-V0.
Advantages
•Excellent accuracy •Very good linearity •Low temperature drift •Optimized response time •Wide frequency bandwidth •No insertion losses
•
High immunity to external interference
•Current overload capability.
Applications
•AC variable speed drives and servo motor drives
•Static converters for DC motor drives •Battery supplied applications •Uninterruptible Power Supplies (UPS)
•
Switched Mode Power Supplies (SMPS)
•
Power supplies for welding applications.
I PN
=
1000
A
020813/5
LEM Components w w w.lem.com
Remarks
•I S is positive when I P flows in the direction of the arrow.•Temperature of the primary conductor should not exceed
100°C.
•Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole.
•This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...),please contact us.
Mechanical characteristics
•General tolerance ± 0.5 mm
•Transducer fastening
Vertical position 2 holes ∅ 5.3 mm 2 M5 steel screws Fastening torque, maxi 4 Nm or 2.52 Lb. - Ft.or
4 holes ∅ 4.2 mm 4 M4 steel screws
Fastening torque, maxi 3.2 Nm or 2.02 Lb. - Ft.
or
4 holes ∅ 2.2
5 mm depth10 mm 4 x PT KA30 screws long 10 mm Fastening torque, maxi 0.9 Nm or 0.57 Lb. - Ft.•Transducer fastening Horizontal position 4 holes ∅ 5.3 mm 4 M5 steel screws Fastening torque, maxi 4 Nm or 2.52 Lb. - Ft.
or
4 holes ∅ 2.2
5 mm depth1
6 mm 4 x PT KA30 screws long 16 mm Fastening torque, maxi 1 Nm or 0.63 Lb. - Ft.•Primary through-hole 40.5 x 40.5 mm •Connection of secondary
Molex 5045-03/AG
Dimensions LF 1005-S (in mm. 1 mm = 0.0394 inch)
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.