最新文章专题视频专题问答1问答10问答100问答1000问答2000关键字专题1关键字专题50关键字专题500关键字专题1500TAG最新视频文章推荐1 推荐3 推荐5 推荐7 推荐9 推荐11 推荐13 推荐15 推荐17 推荐19 推荐21 推荐23 推荐25 推荐27 推荐29 推荐31 推荐33 推荐35 推荐37视频文章20视频文章30视频文章40视频文章50视频文章60 视频文章70视频文章80视频文章90视频文章100视频文章120视频文章140 视频2关键字专题关键字专题tag2tag3文章专题文章专题2文章索引1文章索引2文章索引3文章索引4文章索引5123456789101112131415文章专题3
当前位置: 首页 - 正文

LF 1005-S E

来源:动视网 责编:小OO 时间:2025-09-24 21:00:39
文档

LF 1005-S E

CurrentTransducerLF1005-SFortheelectronicmeasurementofcurrents:DC,AC,pulsed...,withagalvanicisolationbetweentheprimarycircuit(highpower)andthesecondarycircuit(electroniccircuit).ElectricaldataIPNPrimarynominalr.m.s.current1000AIPPrimarycurrent,measu
推荐度:
导读CurrentTransducerLF1005-SFortheelectronicmeasurementofcurrents:DC,AC,pulsed...,withagalvanicisolationbetweentheprimarycircuit(highpower)andthesecondarycircuit(electroniccircuit).ElectricaldataIPNPrimarynominalr.m.s.current1000AIPPrimarycurrent,measu
Current Transducer LF 1005-S

For the electronic measurement of currents : DC, AC, pulsed...,with a galvanic isolation between the primary circuit (high power)and the secondary circuit (electronic circuit).

Electrical data

I PN Primary nominal r.m.s. current 1000A

I P Primary current, measuring range 0 .. ± 1500A

R M

Measuring resistance @ T A = 70°C T A = 85°C

R M min R M max R M min R M max

with ± 15 V @ ± 1000 A max 018015Ω@ ± 1200 A max 0 70 4Ωwith ± 24 V

@ ± 1000 A max 5 60.510 57.5Ω@ ± 1500 A max

5241021

I SN Secondary nominal r.m.s. current 200m A K N Conversion ratio

1 : 5000V C Supply voltage (± 5 %)± 15 .. 24V I C Current consumption

20 (@ ± 24 V ) + I S m A V d

R.m.s. voltage for AC isolation test, 50 Hz, 1 mn 3k V

Accuracy - Dynamic performance data

X G

Overall accuracy @ I PN , T A = 25°C

± 0.4%ε

L

Linearity

< 0.1%Typ

Max I O Offset current @ I P = 0, T A = 25°C ± 0.4m A I OT Thermal drift of I O

- 10°C .. + 85°C ± 0.3

± 0.5

m A t r

Response time 1)

@ 90 % of I PN < 1µs di/dt di/dt accurately followed

> 100A/µs f

Frequency bandwidth (- 1 dB)

DC .. 150

kHz

General data

T A Ambient operating temperature - 10 .. + 85°C T S Ambient storage temperature - 25 .. + 100°C R S Secondary coil resistance @T A = 70°C 48ΩT A = 85°C

51Ωm

Mass

500

g

Standards 2)

EN 50178

Notes :

1)With a di/dt of 100 A/µs

2)

A list of corresponding tests is available.

Features

•Closed loop (compensated) current

transducer using the Hall effect •Insulated plastic case recognized according to UL 94-V0.

Advantages

•Excellent accuracy •Very good linearity •Low temperature drift •Optimized response time •Wide frequency bandwidth •No insertion losses

High immunity to external interference

•Current overload capability.

Applications

•AC variable speed drives and servo motor drives

•Static converters for DC motor drives •Battery supplied applications •Uninterruptible Power Supplies (UPS)

Switched Mode Power Supplies (SMPS)

Power supplies for welding applications.

I PN

=

1000

A

020813/5

LEM Components w w w.lem.com

Remarks

•I S is positive when I P flows in the direction of the arrow.•Temperature of the primary conductor should not exceed

100°C.

•Dynamic performances (di/dt and response time) are best with a single bar completely filling the primary hole.

•This is a standard model. For different versions (supply voltages, turns ratios, unidirectional measurements...),please contact us.

Mechanical characteristics

•General tolerance ± 0.5 mm

•Transducer fastening

Vertical position 2 holes ∅ 5.3 mm 2 M5 steel screws Fastening torque, maxi 4 Nm or 2.52 Lb. - Ft.or

4 holes ∅ 4.2 mm 4 M4 steel screws

Fastening torque, maxi 3.2 Nm or 2.02 Lb. - Ft.

or

4 holes ∅ 2.2

5 mm depth10 mm 4 x PT KA30 screws long 10 mm Fastening torque, maxi 0.9 Nm or 0.57 Lb. - Ft.•Transducer fastening Horizontal position 4 holes ∅ 5.3 mm 4 M5 steel screws Fastening torque, maxi 4 Nm or 2.52 Lb. - Ft.

or

4 holes ∅ 2.2

5 mm depth1

6 mm 4 x PT KA30 screws long 16 mm Fastening torque, maxi 1 Nm or 0.63 Lb. - Ft.•Primary through-hole 40.5 x 40.5 mm •Connection of secondary

Molex 5045-03/AG

Dimensions LF 1005-S (in mm. 1 mm = 0.0394 inch)

LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.