FANS AND BLOWERS DATE: ___________________________
BY:______________ CHK’D____________
JOB NO. ____________________________
CUSTOMER_______________________________ SITE________________________________________________
ITEM NO._________________________ SERVICE_________________________ JOB NO.___________________
NO. REQUIRED___________________ MOLECULAR WEIGHT____________ CORROSIVES PRESENT______
□ DATA BY VENDOR | ○ DATA BY VENDOR | |||||||
□ OPERATING CONDITIONS □CAPACITY (NM3 /MIN)(KG/HR) □SPECIFIC GRAVITY(AIR = 1) □BAROMETER(KG/CM2A) □ELEV. ABOVE SEA LEVEL(M) □RELATIVE HUMIDITY(%) □TEMPERATURE INLET(℃) □PRESS. INLET(KG/CM2 A)(MMH2O)G □PRESSURE DIFFERENTIAL □PRESS. OUTLET(KG/CM2A)(MMH2O)G ○SPEED(RPM) ○WHEEL TIP VELOCITY(/MIN.) ○METRIC BHP(INCLUDE. LOSSES) ○ WATER RATE(KGxMETRICHPxHR) | □TYPE FAN: (CENTRIFUGAL)(VANEAXIAL)(ROTARY) (TUBE AXIAL) (PROPELLER) (OTHER) ○ TYPE BLADES: (BACKWARD CURVED)(RADIAL) (FORWARD CURVED)(LOBE) | |||||||
○CONSTRUCTION DETAILS: DESCRIPTION(SISW)(DIDW) CLASS(І)(Џ)(Ш)(IV) ARRANGEMENT(1)(2)(3)(4)(5)(6)(7)(8)(9) MOTOR LOCATION(W)(X)(Y)(Z) ○WHEEL:(CAST)(FORGED)(RIVETED) DIA. _____________ MMVANE THICKNESS______________ MM ○SHAFT:DIA. AT WHEEL_______MM DIA. AT BRGS. ______ MM SPAN________________ MM OVERHANG________________ MM ○BEARINGS:(INTERNAL)(EXTERNAL) RADIAL(ANTIFRICTION)(ROLLER)(SLEEVE) THRUST________________________________________________ ○SEALS:_________________________________________________ ○ROTATION FACING COUPLING (CW)(CCW) | ||||||||
○ MAX. CAP. (M3/MIN.@INLET)___________________ MAX. METRIC BHP________________ ○ SURGE PT. (M3/MIN.@INLET)___________________ MAX. CONT.SPEEC________________ ○ FAN: 1ST CRITICAL_____________________________ 2ND CRITICAL____________________ □CONTROL: OUTLET DAMPERS(STD.)(STREAM FLOW) VARIABLE INLET VALVES(MANUAL)(AUTO) VARIABLE SPEED DRIVE(YES)(NO) SLIP RING MOTOR(YES)(NO) OTHER__________________________________________________________________________ □CONTROL POWER:_______________VOLTS__________________PH_________________ CPS ELECT. EQUIP. HAZARD CLASS____________________________________________________ | ||||||||
○ MATERIALS OF CONSTRUCTION HOUSING_______________________________________________ BLADES________________________________________________ BLADE TIPS_____________________________________________ GUIDE VANES___________________________________________ SHAFT_________________________________________________ SHAFT SLEEVES________________________________________ OTHER_________________________________________________ | ||||||||
□DRIVER:(MOTOR)(TURBINE) □MAKE_________________________________________ □ TYPE_________________________ ○ RATED METRIC HP____________________ ○ RPM___________________________________ ○ WEIGHT_______________________________________ | ||||||||
○ CONNECTIONS | SIZE | RATING | ORIENTATION | |||||
INLET OUTLET DRAINS | ||||||||
□COUPLING(YES)(NO) □MAKE_________________________________________ □ TYPE_________________________ ○ MODEL________________________________________ | ||||||||
□BELT DRIVE(YES)(NO) ○RULLEY SIZE__________________________________ ○ WEIGHT______________________ □GUARD REQUIRED(STD)(CODE) □STATIC CONDUCTING(YES)(NO) □OTHER___________________________________________________________________________ | □TESTS MECHANICAL RUN IN (YES)(NO) WITNESSED PERFORMANCE (YES)(NO) NON-WITNESSED PERFORMANCE (YES)(NO) SHOP INSPECTION (YES)(NO) OTHER_________________________________________________________ | |||||||
○ FAN OR BLOWER WEIGHT_________________________________________________________ | ||||||||
ITEMS TO BE INCLUDED BY VENDOR: □ COMMON BASEPLATE □ CONTROL PANEL □ PERFORMANCE CURVE □ SECTIONAL DWG. □ OUTLINE DWG. □ INLET FILTER □ SILENCER(INLET)(OUTLET) | □ □ DUCTING TRANSITION PIECE □ VIBRATION ISOLATION ○ INERTIA BLOCKS ○ RAILS □ SPECIAL COATINGS □ COUPLING GUARD(STD.) □ PAINNT (PRIMER)(MRG. STD.) | □ INLET SCREEN □ CONDENSATE DRAIN □ SPARK RESISTANT CONSTRUCTION □ INSULATION STUDS □ INSPECTION ACCESS ○ HEAT SHIELDS ○ BEARING COOLING WHEELS | ||||||
NORMAL CONDITIONS:DRY AT@ 0℃ AND 760 MM HG. | ||||||||
REMARKS:______________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________________________________________________________ | ||||||||
FANS AND BLOWERS DATE: ___________________________
BY:______________ CHK’D____________
JOB NO. ____________________________
OPERATING CONDITIONS.CONTD | ||||||||||||
GAS ANALYSIS ○ MOL% ○____________ | NORMAL | RATED | OTHER CONDITIONS | REMARKS | ||||||||
A | B | C | D | |||||||||
AIR | MW | |||||||||||
OXYGEN | 28,966 | |||||||||||
NITROGEN | 32,000 | |||||||||||
WATERVAPOR | 28,016 | |||||||||||
CARBON MONOXIDE | 18,016 | |||||||||||
CARBON DIOXIDE | 28,010 | |||||||||||
HYDROGEN SULFIDE | 44,010 | |||||||||||
HYDROGEN | 34,076 | |||||||||||
METHANE | 2,016 | |||||||||||
ETHYLENE | 16,012 | |||||||||||
ETHANE | 28,062 | |||||||||||
PROPYLENE | 30,068 | |||||||||||
PROPANE | 42,078 | |||||||||||
i-BUTANE | 44,094 | |||||||||||
n-BUTANE | 53,120 | |||||||||||
i-PENTANE | 72,146 | |||||||||||
n-PENTANE | 72,146 | |||||||||||
HEXANE PLUS | ||||||||||||
TOTAL | ||||||||||||
AVG. MOL WT. | ||||||||||||
LOCATION: | NOISE SPECIFICATIONS: | |||||||||||
○ INDOOR ○ DUTDOOR ○ GRADE | ○ HEATED ○ UNHEATED ○ MEZZANINE | ○ UNDER ROOF ○ PARTIAL SIDES ○ _______________ | ○ APPLICABLE TO MACHINE: SEE SPECIFICATION_______________________________________________________ ○ APPLICABLE TO NEIGHBORHOOD: SEE SPECIFICATION_______________________________________________________ ACOUSTIC HOUSING: ○ YES ○ NO | |||||||||
○ ELECTRICAL AREA CLASS_________ GR. _________ DIV. _________ ○ WINTERIZATION REQD. ○ TROPICALIZATION REQD. | ||||||||||||
SITE DATA: | APPLICABLE SPECIFICATIONS: ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ ____________________________________________________________________________ | |||||||||||
○ELEVATION____________________BAROMETER___________KG/CM2A ○ RANGE OF AMBIENT TEMPS: | ||||||||||||
SITE RATED ℃ NORMAL ℃ MAXIMUM ℃ MINIMUM ℃
| DRY BULB __________ __________ __________ __________ __________ | WET BULB __________ __________ __________ __________ __________ | ||||||||||
UNUSUAL CONDITIONS: ○ DUST ○ FUMES | PAINTING: | |||||||||||
○ OTHER _________________________________________________________ _____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ | ○ MANUFACTURER’S STD. ○ OTHERS_________________________________________________________________ | |||||||||||
SHIPMENT: | ||||||||||||
○ DOMESTIC ○ EXPORT ○ EXPORT BOXING REQD. ○ DUTDOOR STORAGE MORE THAN 3 MONTHS | ||||||||||||
REMARKS:______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ |
MOTOR DATA SHEET DATE__________REV. ________
TO MANUFACTURER SHEET NO.________OF_________
Project No. | For: FAN or BLOWER |
Motor No. | |
1. Rating | ________HP/KW, ________V, ________ Ph., ________Hz, |
Service Conditions | |
2. Duty | ■ Continuous □ Short Time □ Periodic |
3. Location | □ Indoor ■ Outdoor |
4. Environment | |
5. Hazardous Area Classification | ■ Hazardous Cl___1___ Div. ___1____ Gr. __D___ □ Non-hazardous |
6. Ambient Temperature | Max. 40 ℃, Min. 5 ℃, Avg. 30 ℃ |
7. Humidity | 90% |
8. Altitude | 1000 M. Above Sea Level |
Required Characteristics | |
9. Standard / Code | ■ NEMA ■ANSI ■IEEE ■NEC ■IEC □ __________ |
10. Type of Load | |
11. Drived Method | □ Direct □ Belt □ Chain □ Gear |
12. Mounting Type | □ Horizontal □ Vertical □ Foot □ Flange |
13. Starting Method | ■ Across-the-line □Y-△ □ Auto-transformer □ Reactor _____________ |
14. No. of Start / Hour | _______Times |
15. Rotor Type | ■ Squirrel-cage □Wound |
16. Insulation Class | □ B □F ____________ |
17. Max. Temperature Rise | ________℃ |
18. Winding Connection | □Y □ △ |
19. Service Factor | □1.0 □1.10 □1.15 ■1.25 □______ |
20. Slip at Full Load S | Max. |
21. Space Heater | □Yes □No _______V, _______Ph., _______Hz |
22. Enclosure | □TEFC □TENV ■Explosion-proof □WP-I □WP-II □ _____________ _____________ |
23. Rotating Direction | □CW □OCW □Both (Viewed from un-driving end) |
24. Thermal Protection | ■Yes, Type____________ □No |
25. Winding Temperature Detector | □Yes, Type____________ ■No |
26. Bearing Temperature Detector | □Yes, Type____________ ■No |
27. Differential Protection | □Yes, Type____________ ■No |
28. Vibration Detector | □Yes, Type____________ ■No |
29. Surge Protection | □Yes, Type____________ □No |
30. Terminal Box | ■Right □Left (Viewed from un-driving end) |
31. No. of Terminal | □Three □Six |
32. Painting | Munsell No. |
33. Grounding Tap | ■In Terminal Box □On Frame |
34. Test | ■Winding Resistance Measurement ■No-Loading Test □Full-Loading Test ■Locked Rotor Test ■High Potential Test □ |
BY MANUFACTURER SHEET NO.________OF_________
Maker’s Job No. | For |
Motor No. | |
1. Rating | ________HP/KW, ________V, ________ Ph., ________Hz, Syn. Speed _________RPM |
Motor Characteristics | |
2. LRC / FLC | p.u. |
3. LRT / FLT | p.u. |
4. Load | 1/2 ∣ 3/4 ∣ Full |
5. Current (A) | ∣ ∣ |
6. Power Factor (X) | ∣ ∣ |
7. Efficiency (X) | ∣ ∣ |
8. Speed (RPM) | ∣ ∣ |
9.Starting Power Current | __________________ |
10. Max. Voltage Drop Allowable at Starting | |
11. Locked Rotor Current | _____________A, ____________p.u. |
12. Space Heater | □ Yes □No _________V, __________ph., _________Hz |
13. Enclosure | □ TEFC □TENV □Explosion-proof □WP-I □WP-II □ ___________ |
14. Thermal Protection | □Yes, Type____________ □No |
15. Winding Temperature Detector | □Yes, Type____________ □No |
16. Bearing Temperature Detector | □Yes, Type____________ □No |
17. Differential Protection | □Yes, Type____________ □No |
18. Vibration Detector | □Yes, Type____________ □No |
19. Surge Protection | □Yes, Type____________ □No ________ |
20. Frame Size | |
21. Hub Size | In. |
22. Noise Level | dBA. |
23. Bearing type | □Ball □Roller □Sleeve □Thrust □________ |
24. Lubrication Type | □Grease □ __________ |
25. Lube Oil | |
26. Frequency of Lubrication | |
27. Weight | Rotor__________ kg, Total __________ kg |
Remarks |