室外信号电缆加芯原则详见如下几表:
1)普通四线制道岔加芯表
| ZD6-D(A)型电动转辙机芯线配置表 | ||||||||
| 电缆最大长度 | 至电动转辙机电缆芯线数 | |||||||
| 至单动道岔或双动道岔的第一动道岔 | 双动道岔第二动道岔 | |||||||
| 芯线数 | 合计 | 芯线数 | 合计 | |||||
| 去线 | 回线 | 表示线 | 去线 | 回线 | 表示线 | |||
| 604 | 1*2 | 1 | 1 | 4 | 1*2 | 1 | 2 | 5 |
| 805 | 1*2 | 2 | 1 | 5 | 1*2 | 2 | 2 | 6 |
| 906 | 1*2 | 3 | 1 | 6 | 1*2 | 3 | 2 | 7 |
| 1208 | 2*2 | 2 | 1 | 7 | 2*2 | 2 | 2 | 8 |
| 1450 | 2*2 | 3 | 1 | 8 | 2*2 | 3 | 2 | 9 |
| 1611 | 2*2 | 4 | 1 | 9 | 2*2 | 4 | 2 | 10 |
| 1812 | 3*2 | 3 | 1 | 10 | 3*2 | 3 | 2 | 11 |
| 2071 | 3*2 | 4 | 1 | 11 | 3*2 | 4 | 2 | 12 |
| 2265 | 3*2 | 5 | 1 | 12 | 3*2 | 5 | 2 | 13 |
| 2417 | 4*2 | 4 | 1 | 13 | 4*2 | 4 | 2 | 14 |
| 2685 | 4*2 | 5 | 1 | 14 | 4*2 | 5 | 2 | 15 |
| 2900 | 4*2 | 6 | 1 | 15 | 4*2 | 6 | 2 | 16 |
| ZD6-E+J型电动转辙机加芯表 | |||||||||||||||
| 控制距离 | 单动或多动第一动道岔 E机 | 单动道岔第一动道岔 J机 | |||||||||||||
| DD | FD | B | H | DD | FD | 小计 | DB | FB | DB | FB | H | DD | FD | 小计 | |
| X1 | X2 | X3 | X4 | X5 | X6 | C1 | C2 | C3 | C4 | MH | C5 | C6 | |||
| 391 | 1 | 1 | 1 | 1 | 1 | 1 | 6 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 7 |
| 587 | 1 | 1 | 1 | 2 | 1 | 1 | 7 | 1 | 1 | 1 | 1 | 2 | 1 | 1 | 8 |
| 704 | 1 | 1 | 1 | 3 | 1 | 1 | 8 | 1 | 1 | 1 | 1 | 3 | 1 | 1 | 9 |
| 782 | 2 | 2 | 1 | 2 | 2 | 2 | 11 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 10 |
| 1006 | 2 | 2 | 1 | 3 | 2 | 2 | 12 | 1 | 1 | 1 | 1 | 3 | 2 | 2 | 11 |
| 1174 | 2 | 2 | 1 | 4 | 2 | 2 | 13 | 1 | 1 | 1 | 1 | 4 | 2 | 2 | 12 |
| △ | 3 | 3 | 1 | 3 | 3 | 3 | 16 | 1 | 1 | 1 | 1 | 3 | 3 | 3 | 13 |
| 1409 | 3 | 3 | 1 | 4 | 3 | 3 | 17 | 1 | 1 | 1 | 1 | 4 | 3 | 3 | 14 |
| 1601 | 3 | 3 | 1 | 5 | 3 | 3 | 18 | 1 | 1 | 1 | 1 | 5 | 3 | 3 | 15 |
| △ | 4 | 4 | 1 | 4 | 4 | 4 | 21 | 1 | 1 | 1 | 1 | 4 | 4 | 4 | 16 |
| 1806 | 4 | 4 | 1 | 5 | 4 | 4 | 22 | 1 | 1 | 1 | 1 | 5 | 4 | 4 | 17 |
| 2013 | 4 | 4 | 1 | 6 | 4 | 4 | 23 | 1 | 1 | 1 | 1 | 6 | 4 | 4 | 18 |
| ZD6-E+J型电动转辙机加芯表(双动第一动) | |||||||||||||||||
| 控制距离 | 双动第一动道岔 E机 | 双动第一动道岔 J机 | |||||||||||||||
| DD | FD | B | H | DD | FD | 小计 | DD | FD | B | B | H | DD | FD | DD | FD | 小计 | |
| X1 | X2 | X3 | X4 | X5 | X6 | C1 | C2 | C3 | C4 | MH | C5 | C6 | C7 | C8 | |||
| 391 | 1 | 1 | 1 | 1 | 1 | 1 | 6 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 9 |
| 587 | 1 | 1 | 1 | 2 | 1 | 1 | 7 | 1 | 1 | 1 | 1 | 2 | 1 | 1 | 1 | 1 | 10 |
| 704 | 1 | 1 | 1 | 3 | 1 | 1 | 8 | 1 | 1 | 1 | 1 | 3 | 1 | 1 | 1 | 1 | 11 |
| 782 | 2 | 2 | 1 | 2 | 2 | 2 | 11 | 2 | 2 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 16 |
| 1006 | 2 | 2 | 1 | 3 | 2 | 2 | 12 | 2 | 2 | 1 | 1 | 3 | 2 | 2 | 2 | 2 | 17 |
| 1174 | 2 | 2 | 1 | 4 | 2 | 2 | 13 | 2 | 2 | 1 | 1 | 4 | 2 | 2 | 2 | 2 | 18 |
| △ | 3 | 3 | 1 | 3 | 3 | 3 | 16 | 3 | 3 | 1 | 1 | 3 | 3 | 3 | 3 | 3 | 23 |
| 1409 | 3 | 3 | 1 | 4 | 3 | 3 | 17 | 3 | 3 | 1 | 1 | 4 | 3 | 3 | 3 | 3 | 24 |
| 1601 | 3 | 3 | 1 | 5 | 3 | 3 | 18 | 3 | 3 | 1 | 1 | 5 | 3 | 3 | 3 | 3 | 25 |
| △ | 4 | 4 | 1 | 4 | 4 | 4 | 21 | 4 | 4 | 1 | 1 | 4 | 4 | 4 | 4 | 4 | 30 |
| 1806 | 4 | 4 | 1 | 5 | 4 | 4 | 22 | 4 | 4 | 1 | 1 | 5 | 4 | 4 | 4 | 4 | 31 |
| 2013 | 4 | 4 | 1 | 6 | 4 | 4 | 23 | 4 | 4 | 1 | 1 | 6 | 4 | 4 | 4 | 4 | 32 |
| ZD6-E+J型电动转辙机加芯表(双动第二动) | ||||||||||||||||
| 控制距离 | 双动第二动道岔 E机 | 双动第二动道岔 J机 | ||||||||||||||
| DD | FD | B | B | H | DD | FD | 小计 | DD | FD | B | B | H | B | B | 小计 | |
| B1 | B2 | B3 | B4 | MH | B5 | B6 | C5 | C6 | C1 | C2 | MH | C3 | C4 | |||
| 391 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 7 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 7 |
| 587 | 1 | 1 | 1 | 1 | 2 | 1 | 1 | 8 | 1 | 1 | 1 | 1 | 2 | 1 | 1 | 8 |
| 704 | 1 | 1 | 1 | 1 | 3 | 1 | 1 | 9 | 1 | 1 | 1 | 1 | 3 | 1 | 1 | 9 |
| 782 | 2 | 2 | 1 | 1 | 2 | 2 | 2 | 12 | 2 | 2 | 1 | 1 | 2 | 1 | 1 | 10 |
| 1006 | 2 | 2 | 1 | 1 | 3 | 2 | 2 | 13 | 2 | 2 | 1 | 1 | 3 | 1 | 1 | 11 |
| 1174 | 2 | 2 | 1 | 1 | 4 | 2 | 2 | 14 | 2 | 2 | 1 | 1 | 4 | 1 | 1 | 12 |
| △ | 3 | 3 | 1 | 1 | 3 | 3 | 3 | 17 | 3 | 3 | 1 | 1 | 3 | 1 | 1 | 13 |
| 1409 | 3 | 3 | 1 | 1 | 4 | 3 | 3 | 18 | 3 | 3 | 1 | 1 | 4 | 1 | 1 | 14 |
| 1601 | 3 | 3 | 1 | 1 | 5 | 3 | 3 | 19 | 3 | 3 | 1 | 1 | 5 | 1 | 1 | 15 |
| △ | 4 | 4 | 1 | 1 | 4 | 4 | 4 | 22 | 4 | 4 | 1 | 1 | 4 | 1 | 1 | 16 |
| 1806 | 4 | 4 | 1 | 1 | 5 | 4 | 4 | 23 | 4 | 4 | 1 | 1 | 5 | 1 | 1 | 17 |
| 2013 | 4 | 4 | 1 | 1 | 6 | 4 | 4 | 24 | 4 | 4 | 1 | 1 | 6 | 1 | 1 | 18 |
| ZYJ7型电动转辙机加芯表 | ||||||
| 控制距离 | 任一动ZYJ7电动转辙机 | 芯线合计 | ||||
| X1 | X2 | X3 | X4 | X5 | ||
| 2000m | 1 | 1 | 1 | 1 | 1 | 5 |
| 4000m | 2 | 2 | 2 | 2 | 2 | 10 |
| 6000m | 3 | 3 | 3 | 3 | 3 | 15 |
| 色灯信号机加芯表 | |||||||
| 灯泡规格 | 同时点灯数 | 供电电压(V) | 变压器一次侧电压(V) | 灯丝继电器压降(V) | 回路电流(A) | 电缆控制距离 | |
| ZQ=1 | ZQ=1 | ||||||
| ZH=1 | ZH=2 | ||||||
| 12V25W | 1 | 220 | 180 | 5 | 0.158 | 4713 | 6284 |
| 2 | 220 | 180 | 5 | 0.316 | 3142 | 4713 | |
| 3 | 220 | 180 | 5 | 0.47 | 2356 | ||
| 4 | 220 | 180 | 5 | 0.63 | 1885 | ||
(1)电源屏至送电端轨道变压器I次侧的电缆允许压降为30V。
计算干线供电的电缆芯线时,每段轨道道路所需电流应分别按下列给出值考虑:电化区段 0.10A;非电化区段 0.14A,电缆电阻为23.5欧/km。主要在非电码化区段考虑,电码化区段送电端均要发码,没有送电电缆合用现象,一根送电电缆最长为L=30/(23.5*2*0.1)=6.38km。非电码化区段有送电电缆合用时,计算公式为:30=23.5*2*(N1*L1*0.1+N2*L2*0.1+……)注:N为每段所含区段数,L为每段长度,去线回线均考虑电阻,所以乘以2,Nx一般为送电合用径路上的最远送电端。
(2)受电端轨道变压器至继电器室的电缆电阻应不大于150欧。
单拉公式:L=150欧/(23.5欧/km *2)=3.19km(即受电端去、回线均单拉时能满足的最大长度)。