Sometimes we get so busy or absorbed in other things, we forget that the cause can help with the solution. Common check valve problems include noise (water hammer), vibration, reverse flow, sticking, leakage, missing internals, component wear, or damage. However, it is worth mentioning that normally the real cause is the wrong style check valve for the application. In such cases, the problem is the application, not the check valve.
Two of the most common problems with check valves are reverse flow and water hammer. In both situations, a fast-closing valve is desired. Reverse flow can be costly, especially if it occurs at the discharge of a pump and the pump spins backwards. The cost to repair or replace the pump, plus the plant downtime, far exceeds the cost of installing the right check valve in the first place. With water hammer, you need a faster-closing check valve to prevent pressure surges and the resulting shock waves that occur when the disc slams into the seat, sending noise, vibration, and hammering sounds that can rupture pipelines and damage equipment and pipe supports.
If the internals are missing or exhibiting wear, two factors may be occurring. First, if the check valve selected does not have enough flow passing through to keep it against its stop, a valve with a lower Cv is needed to prevent the moving/fluttering of the internals. Second, if the check valve is used at the discharge of a reciprocating air or gas compressor, a valve with a damped design or dashpot to handle high-frequency cycling is needed.
Sticking can occur when scale or dirt is trapped between the disc and body bore. Leakage can happen from damage to the seat or disc or simple trash in the line. An elastomer is needed to provide zero leakage.