最新文章专题视频专题问答1问答10问答100问答1000问答2000关键字专题1关键字专题50关键字专题500关键字专题1500TAG最新视频文章推荐1 推荐3 推荐5 推荐7 推荐9 推荐11 推荐13 推荐15 推荐17 推荐19 推荐21 推荐23 推荐25 推荐27 推荐29 推荐31 推荐33 推荐35 推荐37视频文章20视频文章30视频文章40视频文章50视频文章60 视频文章70视频文章80视频文章90视频文章100视频文章120视频文章140 视频2关键字专题关键字专题tag2tag3文章专题文章专题2文章索引1文章索引2文章索引3文章索引4文章索引5123456789101112131415文章专题3
当前位置: 首页 - 正文

4972 4983 4980 4928 ROHS 2010

来源:动视网 责编:小OO 时间:2025-10-02 00:52:35
文档

4972 4983 4980 4928 ROHS 2010

TestReportNumber:TWNC00149239AuthorizedBy:OnBehalfOfIntertekTestingServicesTaiwanLimitedK.Y.LiangDirectorThisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofthelaboratory.Page1Of5IntertekTestingServicesTaiwanLtd.8F.,No.423,Ruiguang
推荐度:
导读TestReportNumber:TWNC00149239AuthorizedBy:OnBehalfOfIntertekTestingServicesTaiwanLimitedK.Y.LiangDirectorThisreportshallnotbereproducedexceptinfull,withoutthewrittenapprovalofthelaboratory.Page1Of5IntertekTestingServicesTaiwanLtd.8F.,No.423,Ruiguang


Test Report Number : TWNC00149239

Authorized By:

On Behalf Of Intertek Testing Services

Taiwan Limited

K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory.

Page 1 Of 5

Intertek Testing Services Taiwan Ltd.

8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.

Applicant: tesa SE Date : Mar 05, 2010

Quickbornstrasse 24

20253 Hamburg Germany

Sample Description:

One (1) group of submitted samples said to be : Sample Description : Double-sided tape Style / Item No. : tesa4983,tesa4972,tesa4980,tesa4928 Date Sample Received : Feb 26, 2010 Date Test Started : Mar 01, 2010

Test Conducted :

As requested by the applicant, for details please refer to attached pages.

Number :TWNC00149239

Test Conducted

Page 2 Of 5

Intertek Testing Services Taiwan Ltd.

8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.

(Ⅰ) Test Result Summary :

Result (ppm) Testing Item

Submitted Samples (Release Liners Were Excluded)

Heavy Metal

Cadmium (Cd) content ND Lead (Pb) content ND Mercury (Hg) content

ND Chromium VI (Cr 6+) content ND Polybrominated Biphenyls (PBBs)

Monobrominated Biphenyls (MonoBB) ND Dibrominated Biphenyls (DiBB) ND Tribrominated Biphenyls (TriBB)

ND Tetrabrominated Biphenyls (TetraBB) ND Pentabrominated Biphenyls (PentaBB) ND Hexabrominated Biphenyls (HexaBB) ND Heptabrominated Biphenyls (HeptaBB) ND Octabrominated Biphenyls (OctaBB) ND Nonabrominated Biphenyls (NonaBB) ND Decabrominated Biphenyl (DecaBB)

ND Polybrominated Diphenyl Ethers (PBDEs)

Monobrominated Diphenyl Ethers (MonoBDE) ND Dibrominated Diphenyl Ethers (DiBDE) ND Tribrominated Diphenyl Ethers (TriBDE)

ND Tetrabrominated Diphenyl Ethers (TetraBDE) ND Pentabrominated Diphenyl Ethers (PentaBDE) ND Hexabrominated Diphenyl Ethers (HexaBDE) ND Heptabrominated Diphenyl Ethers (HeptaBDE) ND Octabrominated Diphenyl Ethers (OctaBDE) ND Nonabrominated Diphenyl Ethers (NonaBDE) ND Decabrominated Diphenyl Ether (DecaBDE) ND

Remarks:ppm = parts per million based on weight of tested sample = mg/kg ND = Not Detected Responsibility Of Chemist :Irene Chiou / Kevin Liu / Cathy Chen

Date Sample Received : Feb 26, 2010 Testing Period : Mar 01, 2010 To Mar 05, 2010

Number :TWNC00149239

Test Conducted

Page 3 Of 5

Intertek Testing Services Taiwan Ltd.

8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.

(Ⅱ) RoHS Requirement:

Restricted Substances Limits Cadmium (Cd) Content 0.01% (100ppm) Lead (Pb) Content 0.1% (1000ppm) Mercury (Hg) Content 0.1% (1000ppm)

Chromium VI (Cr 6+

) Content 0.1% (1000ppm) Polybrominated Biphenyls (PBBs) 0.1% (1000ppm) Polybrominated Diphenyl Ehters (PBDEs) 0.1% (1000ppm)

The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material.

(Ⅲ) Test Method:

Testing Item Testing

Method MDL Cadmium (Cd) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by

microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

2 ppm

Lead (Pb) content With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by

microwave digestion until the tested samples are totally dissolved and determined by ICP-OES.

2 ppm

Mercury (Hg) content With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave

digestion until the tested samples are totally dissolved and determined by ICP-OES.

2 ppm

Chromium VI (Cr 6+

) content With reference to IEC 62321 edition

1.0:2008 in annex C, by alkaline digestion and determined by UV-Vis

spectrophotometer.

1 ppm Polybrominated

Biphenyls (PBBs)

With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent

extraction and determined by GC-MSD and further HPLC confirmation when necessary.

5 ppm Polybrominated Diphenyl Ethers (PBDEs) With reference to IEC 62321 edition

1.0:2008 in annex A, by solvent extraction and determined by GC-MSD and further HPLC confirmation when

necessary.

5 ppm

Remark: MDL = Quantitation Limit Of Testing Method

Number :TWNC00149239

Test Conducted

Page 4 Of 5

Intertek Testing Services Taiwan Ltd.

8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.

(Ⅳ) Measurement Flowchart:

Test For Cd/Pb/Hg/Chromium (VI)/PBBs/PBDEs Contents Reference Standard: IEC 62321 edition 1.0:2008

End Of Report

Number :TWNC00149239

Test Conducted

Page 5 Of 5

Intertek Testing Services Taiwan Ltd.

8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C.