一、设备操作系统版本
| 检查项目 | 操作系统版本 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show version |show bootflash |
| H3C: dispaly version | display boot-loader | |
| 测试结果 | 所有实时输出结果为正常 |
| 备注 | 显示ISO版本、路由器持续运行时间、最近一次重启动的原因、路由器主存的大小、共享存储器的大小、内存的大小、ISO映像的文件名,以及路由器从何处启动等信息 |
NW-C-R-7606-A#show version
Cisco IOS Software, c7600rsp72043_rp Software (c7600rsp72043_rp-IPSERVICESK9-M), Version 15.0(1)S, RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2010 by Cisco Systems, Inc.
Compiled Thu 29-Jul-10 05:06 by prod_rel_team
ROM: System Bootstrap, Version 12.2(33r)SRD5, RELEASE SOFTWARE (fc1)
BOOTLDR: Cisco IOS Software, c7600rsp72043_rp Software (c7600rsp72043_rp-IPSERVICESK9-M), Version 15.0(1)S, RELEASE SOFTWARE (fc1)
JSNW-C-R-7606-A uptime is 41 weeks, 2 hours, 21 minutes
Uptime for this control processor is 41 weeks, 40 minutes
System returned to ROM by power cycle (SP by power on)
System image file is "sup-bootdisk:c7600rsp72043-ipservicesk9-mz.150-1.S.bin"
Last reload type: Normal Reload
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
If you require further assistance please contact us by sending email to
****************.
Cisco CISCO7606-S (M8500) processor (revision 1.1) with 917504K/65536K bytes of memory.
Processor board ID FOX1412GGFJ
BASEBOARD: RSP720
CPU: MPC8548_E, Version: 2.1, (0x80390021)
CORE: E500, Version: 2.2, (0x80210022)
CPU:1200MHz, CCB:400MHz, DDR:200MHz,
Last reset from power-on
1 SIP-200 controller (2 Channelized OC3/STM-1).
1 Virtual Ethernet interface
52 Gigabit Ethernet interfaces
105 Serial interfaces
2 Channelized STM-1 ports
2 Channelized STM-1 ports
39K bytes of non-volatile configuration memory.
507024K bytes of Internal ATA PCMCIA card (Sector size 512 bytes).
Configuration register is 0x2102
NW-C-S-6506A#show bootflash:
device not bootable, device format is from a different router type
-#- ED ----type---- --crc--- -seek-- nlen -length- ---------date/time--------- name
1 .. image 1F70D9 288FC90 32 42007568 Jul 15 2005 04:37:53 +08:00 s72033-pk9sv-mz.122-17d.SXB8.bin
2 .. crashinfo D1F15CC3 28D9DEC 25 303321 May 3 2000 09:50:17 +08:00 crashinfo_20000503-015017
23224852 bytes available (42311148 bytes used)
2.H3C输出
KMServer-S7506E-A]dis version
H3C Comware Platform Software
Comware Software, Version 5.20, Release 6616P05
Copyright (c) 2004-2011 Hangzhou H3C Tech. Co., Ltd. All rights reserved.
H3C S7506E uptime is 16 weeks, 1 day, 3 hours, 39 minutes
MPU(M) 0:
Uptime is 16 weeks,1 days,3 hours,39 minutes
H3C S7506E MPU(M) with 1 BCM1125H Processor
DRAM: 512M bytes
FLASH: M bytes
NVRAM: 512K bytes
Slot 1 Without Board
LPU 2:
Uptime is 16 weeks,1 days,3 hours,43 minutes
H3C S7506E LPU with 1 BCM1122 Processor
Slot 3 Without Board
Slot 4 Without Board
LPU 5:
Uptime is 16 weeks,1 days,3 hours,43 minutes
H3C S7506E LPU with 1 BCM1122 Processor
Slot 6 Without Board
Slot 7 Without Board
LPU 8:
Uptime is 16 weeks,1 days,3 hours,42 minutes
H3C S7506E LPU with 1 BCM1122 Processor
Slot 9 Without Board
[KMServer-S7506E-A]dis boot-loader
The primary app to boot of board 0 at this time is: flash:/s7500e-cmw520-r6616p05.app
二、设备CPU利用状况检查
| 检查项目 | 设备CPU利用状况检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show processes cpu history |
| H3C: display cpu-usage history | |
| 测试结果 | CPU利用率为平均<50%,最高不超过70%为正常 |
| 备注 | 检查设备最近(CISCO 72小时)(h3c 60分钟)内CPU是否过载。 |
JSNW-C-R-7606-A#show processes cpu history
111111 1111155555 11111 11111
90
80
70
60
50
40
30
20
10 *****
0 5 0 5 0 5 0 5 0 5 0
90
80
70
60
50
40
30
20
10 *
0 5 0 5 0 5 0 5 0 5 0
* = maximum CPU% # = average CPU%
90
80
70
60
50
40
30
20
10 ** * * ******* * * ***** **** ***** * ***** * * * ** *
0 5 0 5 0 5 0 5 0 5 0 5 0
* = maximum CPU% # = average CPU%
2.H3C输出
[KMServer-S7506E-A]display cpu-usage history
100%|
95%|
90%|
85%|
80%|
75%|
70%|
65%|
60%|
55%|
50%|
45%|
40%|
35%|
30%|
25%|
20%|
15%|
10%|
5%| ## ### ### #### ## # ####
10 20 30 40 50 60 (minutes)
[KMServer-S7506E-A]
三、设备memory利用状况检查
| 检查项目 | 设备memory利用状况检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show memory statistics history |
| H3C: display memory | |
| 测试结果 | 可用memory为平均>50%,最低不低于30%为正常 |
| 备注 | 检查设备最近72小时内memory是否过载;H3C只能看到当前使用情况。 |
NW-C-R-7606-A#show memory statistics
Head Total(b) Used(b) Free(b) Lowest(b) Largest(b)
Processor 13412EE8 683594008 163583032 520010976 503185944 5020308
I/O 3C000000 671088 39676044 27432820 27432820 27225020
JSNW-C-R-7606-A#show memory statistics history
------------------ History of Processor Mempool ------------------
90
0 5 0 5 0 5 0 5 0 5 0
90
0 5 0 5 0 5 0 5 0 5 0
90
0 5 0 5 0 5 0 5 0 5 0 5 0
------------------ History of I/O Mempool ------------------
90
80
70
60
50
0 5 0 5 0 5 0 5 0 5 0
90
80
70
60
50
0 5 0 5 0 5 0 5 0 5 0
90
80
70
60
50
0 5 0 5 0 5 0 5 0 5 0 5 0
4.H3C输出
[KMServer-S7506E-A]dis memory
System Total Memory(bytes): 434502480
Total Used Memory(bytes): 103569732
Used Rate: 23%
四、设备模块运行状况检查
| 检查项目 | 设备模块运行状态检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show module (show inventory) |
| H3C: display device manuinfo| dis device | |
| 测试结果 | 所有设备模块运行状态OK |
| 备注 | 可以列出各个模块的序列号等信息 |
JSNW-C-R-7606-A#show module
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 0 4-subslot SPA Interface Processor-200 7600-SIP-200 JAE1453059O
4 48 CEF720 48 port 10/100/1000mb Ethernet WS-X6748-GE-TX SAL1429N6UN
5 2 Route Switch Processor 720 (Active) RSP720-3C-GE SAL1521E3WU
6 2 Route Switch Processor 720 (Cold) RSP720-3C-GE JAE145209F1
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
1 cc.1d2a.f180 to cc.1d2a.f1bf 2.303 15.0(1)S 15.0(1)S Ok
4 5475.d0cb.67c8 to 5475.d0cb.67f7 3.4 12.2(18r)S1 15.0(1)S Ok
5 cc.1dfb.c8 to cc.1dfb.cb 5.12 12.2(33r)SRD 15.0(1)S Ok
6 68ef.bdd3.7b94 to 68ef.bdd3.7b97 5.12 12.2(33r)SRD 15.0(1)S Ok
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
1/0 1xCHSTM1 SPA SPA-1XCHSTM1/OC3 JAE1232RFLR 2.0 Ok
1/1 1xCHSTM1 SPA SPA-1XCHSTM1/OC3 JAB100809GH 1.0 Ok
4 Centralized Forwarding Card WS-F6700-CFC SAL1430NR2Z 4.1 Ok
5 Policy Feature Card 3 7600-PFC3C SAL1521E6Y5 1.2 Ok
5 C7600 MSFC4 Daughterboard 7600-MSFC4 SAL1519DKNN 1.6 Ok
6 Policy Feature Card 3 7600-PFC3C JAE145200AR 1.2 Ok
6 C7600 MSFC4 Daughterboard 7600-MSFC4 JAE145204CF 1.6 Ok
Mod Online Diag Status
---- -------------------
1 Pass
1/0 Pass
1/1 Pass
4 Pass
5 Pass
6 Pass
2.H3C输出
[KMCore-S12508]display device manuinfo
Chassis 1:
Chassis self:
DEVICE_SERIAL_NUMBER : 210235A0E6X127000036
Slot 0:
DEVICE_SERIAL_NUMBER : 210231A9680107000050
Slot 2:
DEVICE_SERIAL_NUMBER : 210231A1HDH127000011
Slot 3:
DEVICE_SERIAL_NUMBER : 210231A1HDH121000038
Slot 6:
DEVICE_SERIAL_NUMBER : 210231A981H127000016
KMServer-S7506E-A]dis device
Slot No. Brd Type Brd Status Subslot Num Sft Ver Patch Ver
0 LSQ1SRP2XB Master 0 S7500E-6616P05 None
1 NONE Absent 0 NONE None
2 LSQ1GP48SC Normal 0 S7500E-6616P05 None
3 NONE Absent 0 NONE None
4 NONE Absent 0 NONE None
5 LSQ1GV48SC Normal 0 S7500E-6616P05 None
6 NONE Absent 0 NONE None
7 NONE Absent 0 NONE None
8 SRP2XBSLAVE Normal 0 S7500E-6616P05 None
9 NONE Absent 0 NONE None
五、设备系统内各模块温度检查
| 检查项目 | 设备系统电源及风扇与设备内各模块温度检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show environment |
| H3C: dis environment| display fan | dis power-supply verbose | |
| 测试结果 | 电源风扇运行正常,设备内部各部分模块工作温度小于45℃ |
| 备注 |
environmental alarms:
no alarms
backplane:
operating clock count: 2
fan-tray 1:
fan-tray 1 type: FAN-MOD-6SHS
fan-tray 1 mode: Auto
fan-tray 1 fan-fail: OK
clock 1:
clock 1 OK: OK, clock 1 clock-inuse: in-use
clock 2:
clock 2 OK: OK, clock 2 clock-inuse: not-in-use
power-supply 1:
power-supply 1 fan-fail: OK
power-supply 1 power-input: AC 220V
power-supply 1 power-output-mode: high
power-supply 1 incompatible with fan: OK
power-supply 1 power-output-fail: OK
power-supply 2:
power-supply 2 fan-fail: OK
power-supply 2 power-input: AC 220V
power-supply 2 power-output-mode: high
power-supply 2 incompatible with fan: OK
power-supply 2 power-output-fail: OK
module 1:
module 1 power-output-fail: OK
module 1 outlet temperature: 31C
module 1 inlet temperature: 23C
module 1 device-1 temperature: 23C
module 1 device-2 temperature: 24C
module 4:
module 4 power-output-fail: OK
module 4 outlet temperature: 41C
module 4 inlet temperature: 25C
module 5:
module 5 power-output-fail: OK
module 5 outlet temperature: 30C
module 5 inlet temperature: 26C
module 5 device-1 temperature: 34C
module 5 device-2 temperature: 34C
module 5 asic-1 (SSO-1) temp: 26C
module 5 asic-2 (SSO-2) temp: 26C
module 5 asic-3 (SSO-3) temp: 26C
module 5 asic-4 (SSO-4) temp: 25C
module 5 asic-5 (SSA-1) temp: 25C
module 5 asic-6 (HYPERION-1) temp: 25C
module 5 RP outlet temperature: 31C
module 5 RP inlet temperature: 29C
module 5 EARL outlet temperature: 32C
module 5 EARL inlet temperature: 27C
module 6:
module 6 power-output-fail: OK
module 6 outlet temperature: 33C
module 6 inlet temperature: 26C
module 6 device-1 temperature: 39C
module 6 device-2 temperature: 39C
module 6 asic-1 (SSO-1) temp: 27C
module 6 asic-2 (SSO-2) temp: 27C
module 6 asic-3 (SSO-3) temp: 27C
module 6 asic-4 (SSO-4) temp: 27C
module 6 asic-5 (SSA-1) temp: 27C
module 6 asic-6 (HYPERION-1) temp: 27C
module 6 RP outlet temperature: 31C
module 6 RP inlet temperature: 28C
module 6 EARL outlet temperature: 32C
module 6 EARL inlet temperature: 27C
SPA-1XCHSTM1/OC3[1/0] temperature sensor 0, reading: 45C
SPA-1XCHSTM1/OC3[1/0] temperature sensor 1, reading: 37C
SPA-1XCHSTM1/OC3[1/0] temperature sensor 2, reading: 46C
SPA-1XCHSTM1/OC3[1/0] temperature sensor 3, reading: 41C
SPA-1XCHSTM1/OC3[1/0] temperature sensor 4, reading: 50C
SPA-1XCHSTM1/OC3[1/0] nominal: 3.300V, reading: 3.271V
SPA-1XCHSTM1/OC3[1/0] nominal: 2.500V, reading: 2.484V
SPA-1XCHSTM1/OC3[1/0] nominal: 1.800V, reading: 1.788V
SPA-1XCHSTM1/OC3[1/0] nominal: 1.500V, reading: 1.4V
SPA-1XCHSTM1/OC3[1/0] nominal: 3.300V, reading: 3.291V
SPA-1XCHSTM1/OC3[1/1] temperature sensor 0, reading: 43C
SPA-1XCHSTM1/OC3[1/1] temperature sensor 1, reading: 33C
SPA-1XCHSTM1/OC3[1/1] temperature sensor 2, reading: 43C
SPA-1XCHSTM1/OC3[1/1] temperature sensor 3, reading: 40C
SPA-1XCHSTM1/OC3[1/1] temperature sensor 4, reading: 44C
SPA-1XCHSTM1/OC3[1/1] nominal: 3.300V, reading: 3.284V
SPA-1XCHSTM1/OC3[1/1] nominal: 2.500V, reading: 2.498V
SPA-1XCHSTM1/OC3[1/1] nominal: 1.800V, reading: 1.779V
SPA-1XCHSTM1/OC3[1/1] nominal: 1.500V, reading: 1.498V
SPA-1XCHSTM1/OC3[1/1] nominal: 3.300V, reading: 3.298V
chassis connector rating: 1680.00 Watts (40.00 Amps @ 42V)
module 1
module 1 connector rating: 1512.00 Watts (36.00 Amps @ 42V)
module 1 power consumption: 240.24 Watts ( 5.72 Amps @ 42V)
module 4
module 4 connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 4 power consumption: 325.50 Watts ( 7.75 Amps @ 42V)
module 5
module 5 connector rating: 1260.00 Watts (30.00 Amps @ 42V)
module 5 power consumption: 310.38 Watts ( 7.39 Amps @ 42V)
module 6
module 6 connector rating: 1260.00 Watts (30.00 Amps @ 42V)
module 6 power consumption: 310.38 Watts ( 7.39 Amps @ 42V)
chassis per slot cooling capacity: 91 cfm
ambient temperature: < 55C
module 1 cooling requirement: 30 cfm
module 4 cooling requirement: 70 cfm
module 5 cooling requirement: 35 cfm
module 6 cooling requirement: 35 cfm
JSNW-C-R-7606-A#
2.H3C输出
KMCore-S12508]dis environment
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
1/0 inflow 1 23 -25 70 80 N/A
1/0 outflow 1 28 -15 70 85 N/A
1/0 hotspot 1 29 -15 75 85 N/A
1/2 inflow 1 26 -15 70 90 N/A
1/2 outflow 1 49 30 85 90 N/A
1/2 hotspot 1 27 -15 80 85 N/A
1/2 hotspot 2 37 10 80 85 N/A
1/3 inflow 1 27 -15 70 90 N/A
1/3 outflow 1 51 30 85 90 N/A
1/3 hotspot 1 27 -15 80 85 N/A
1/3 hotspot 2 37 10 80 85 N/A
1/6 inflow 1 26 -15 65 80 N/A
1/6 outflow 1 31 -5 70 80 N/A
1/6 hotspot 1 28 -15 65 75 N/A
1/7 inflow 1 27 -20 65 85 N/A
1/7 outflow 1 37 0 70 85 N/A
1/7 hotspot 1 32 -10 70 80 N/A
1/10 inflow 1 27 -10 55 80 N/A
1/10 outflow 1 51 5 85 95 N/A
[KMServer-S7506E-A]display fan
Normal
[KMCore-S12508]dis power-supply verbose
Power info on chassis 1:
System power-supply policy: enable
System power-module redundant(configured): 1
System power usable: 10000 Watts
System power redundant(actual): 2000 Watts
System power allocated: 1900 Watts
System power available: 8100 Watts
SYSTEM POWER USED(CURRENT): 1029.39 Watts
System power monitoring unit 1:
---------- ------ ------------ -------- ------ -----------------
PSE9000-A AC/DC 220(default) 6 5 1
DC output voltage information:
Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status
---- -------- ------------------ ------------------ -------
1 49.97 51.00 49.00 Normal
DC output current information:
Total current(A): 20.60
PSU Status:
--- ------- ----------- ---------- ---------------- ------- ------ -------------
1/1 Normal
1/2 Normal
1/3 Normal
1/4 Normal
1/5 Normal
1/6 Normal
Line-card power status:
---- --------------- ----- ------
2 LST2XP8LEB1 240 On
3 LST2XP8LEB1 240 On
4 None -- Absent
5 None -- Absent
6 LST1GP48LEB1 170 On
7 LST1GT48LEB1 175 On
8 None -- Absent
9 None -- Absent
Power info on chassis 2:
System power-supply policy: enable
System power-module redundant(configured): 1
System power usable: 4000 Watts
System power redundant(actual): 2000 Watts
System power allocated: 1940 Watts
System power available: 2060 Watts
SYSTEM POWER USED(CURRENT): 1096.52 Watts
System power monitoring unit 1:
---------- ------ ------------ -------- ------ -----------------
PSE9000-A AC/DC 220(default) 3 2 1
DC output voltage information:
Tray Value(V) Upper-Threshold(V) Lower-Threshold(V) Status
---- -------- ------------------ ------------------ -------
1 49.84 51.00 49.00 Normal
DC output current information:
Total current(A): 22.00
PSU Status:
--- ------- ----------- ---------- ---------------- ------- ------ -------------
1/1 Absent
1/2 Normal
1/4 Normal
1/5 Absent
1/6 Normal
Line-card power status:
---- --------------- ----- ------
2 LST2XP8LEB1 240 On
3 LST1XP8LEB1 280 On
4 None -- Absent
5 None -- Absent
6 LST1GP48LEB1 170 On
7 LST1GT48LEB1 175 On
8 None -- Absent
9 None -- Absent
[KMCore-S12508]
六、设备系统log检查
| 检查项目 | 设备系统log检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show logging |
| H3C: display logbuffer | |
| 测试结果 | 无未处理及异常的告警 |
| 备注 |
| 检查项目 | 设备高可用状态检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: show standby |
| H3C: | |
| 测试结果 | 主设备的VLAN处于Active状态,备设备的VLAN处于Standby状态 |
| 备注 |
JSNW-C-S-6506A#show standby
Vlan2 - Group 0
State is Active
Virtual IP address is 88.32.2.254
Active virtual MAC address is 0000.0c07.ac00
Hello time 3 sec, hold time 10 sec
Preemption enabled
Active router is local
Standby router is 88.32.2.253, priority 100 (expires in 10.816 sec)
Priority 120 (configured 120)
IP redundancy name is "hsrp-Vl2-0" (default)
2.H3C输出
[KMServer-S7506E-A]display vrrp
IPv4 Standby Information:
Run Mode : Standard
Run Method : Virtual MAC
Total number of virtual routers : 1
Interface VRID State Run Adver Auth Virtual
Pri Timer Type IP
---------------------------------------------------------------------
Vlan20 1 Master 120 1 None 172.16.20.254
八、网络连通性检查
| 检查项目 | 网络连通性检查 |
| 检查对象 | 维保功能区域中的路由器、交换机 |
| 检查命令 | CISCO: ping 88.32.1.1 repeat 1000 |
| H3C: ping -c 1000 172.16.254.1 | |
| 测试结果 | 在局域网内平均包返回时间在10毫秒内,丢包率小于1% |
| 备注 |